Model Number | X-1.2KVA-M, X-2.4KVA-M |
---|---|
Rated Power | 1200VA / 900W, 2400VA / 1600W |
Voltage | 230 VAC |
Selectable Voltage Range | 90-280 VAC or 170-280 VAC |
Frequency Range | 50 Hz/60 Hz (Auto sensing) |
AC Voltage Regulation (Batt. Mode) | 230VAC ± 10% |
Overload Capability | Load >110% ±15%, alarm 5 min then fault;Load >130% ±15%, fault immediately |
Efficiency (Peak) | 82%, 85% |
Transfer Time | 20 ms |
Waveform | Simulated sine wave |
Battery Voltage | 12 VDC, 24 VDC |
Floating Charge Voltage | 13.7 VDC ± 0.5 VDC, 27.4 VDC ± 1 VDC |
Overcharge Protection | 15.0 VDC ± 0.5 VDC, 30.0 VDC ± 0.5 VDC |
Solar Charger Type | MPPT |
Maximum PV Array Open Circuit Voltage | 100 VDC |
Maximum PV Array Power | 1440 W, 720 W |
MPPT Range @ Operating Voltage | 15 ~ 80 VDC, 30 ~ 80 VDC |
Maximum Solar Charge Current | 60A |
Maximum AC Charge Current | 10A/25A |
Maximum Charge Current | 60A |
Humidity | 0 to 90% Relative Humidity (Non-condensing) |
Operating Temperature | 0℃ to 40℃ |
Storage Temperature | -15℃ to 55℃ |